Connecticut Electric THQP230 General Electric Circuit Breaker, 30 amp Review

Connecticut Electric THQP230 General Electric Circuit Breaker, 30 amp

    This fits your .
  • Make sure this fits by entering your model number.
  • The product is good to use
  • The product is highly durable
  • Manufactured in China

See more product details

Product Description

GE, 30a, double pole circuit breaker, 240V, bulk. The product is good to use. The product is highly durable. Manufactured in china.

From the Manufacturer

This 120/240-Volt GE 30 amp, double pole, thin series replacement circuit breaker is used in a General Electric load center. Typical applications, up to 8,800-Watt, include electric baseboard heat, fan forced heat and 240-Volt air conditioners (up to 23,000 BTU). These are only suggested applications and cannot assure compliance with all local codes. Please check local electrical codes before starting any electrical project.

Connecticut Electric UBITB-A130R Connecticut Ubitba130R Type Ubitba Left Clip Circuit Breaker, 120/240 Vac, 30 A, 1 P, 10 Ka, Amp Review

Connecticut Electric UBITB-A130R Connecticut Ubitba130R Type Ubitba Left Clip Circuit Breaker, 120/240 Vac, 30 A, 1 P, 10 Ka, Amp

    This fits your .
  • Make sure this fits by entering your model number.
  • Replacement Challenger mh130-r Type a circuit breaker manufactured new by CONNECTICUT ELECTRIC
  • For use in Challenger Type a circuit breaker panels
  • Intertek ETL listing to UL standard 489-molded case circuit breakers

See more product details

Product Description

Connecticut circuit breaker, type ubitba, left clip, 120/240 vac, 30 a, 1 phase, 10 ka interrupt, 1 poles, 10 – 2 AWG wire, plug in mounting, 3-D/4 in overall length, 1/2 in overall width, 2-1/2 in overall depth, ETL/UL listed, for Thomas and betts Challenger load centers, well pumps, bathroom heaters and electric motors. CONNECTICUT ELECTRIC manufactures new high quality replacement circuit breakers for Challenger load centers that accept Challenger type a style circuit breakers. Circuit breakers should only be replaced with new tested and safety agency listed circuit breakers, never used or refurbished ones.

From the Manufacturer

This 120 volt Challenger “A” Series 30 amp, single pole, With Right Side Clip, replacement circuit breaker is used in a Challenger load center. Typical applications, up to 3,600 watts, include well pumps (up to 200′), bathroom heaters and electric motors (1-1/2 hp to 2 hp). These are only suggested applications and cannot assure compliance with all local codes. Please check local electrical codes before starting any electrical project.

Connecticut Electric THQL1130 Circuit Breaker, 30 amp, Black Review

Connecticut Electric THQL1130 Circuit Breaker, 30 amp, Black

    This fits your .
  • Make sure this fits by entering your model number.
  • N/A
  • Made in USA or Imported
  • The product is good to use
  • The product is highly durable
  • Manufactured in China

See more product details

Product Description

GE, 30a single pole circuit breaker, 1 inch per pole, 120V, bulk. The product is good to use. Manufactured in china.

From the Manufacturer

This 120 volt GE 30 amp, single pole, thick series replacement circuit breaker is used in a General Electric load center. Typical applications, up to 2,200 watts, include kitchen circuits, branch circuits, wall receptacles, electric heaters (up to 1,650 watts), dishwashers, refrigerators, freezers, washing machines, window air conditioners (110V, up to 5,500 BTU) and electric motors (3/4 hp to 1-1/4 hp). These are only suggested applications and cannot assure compliance with all local codes. Please check local electrical codes before starting any electrical project.

UBIF240N-New Federal Pacific Electric Stab-Lok NA240 Replacement. Two Pole 40 Amp Thick Series Manufactured by Connecticut Electric. Review

UBIF240N-New Federal Pacific Electric Stab-Lok NA240 Replacement. Two Pole 40 Amp Thick Series Manufactured by Connecticut Electric.

    This fits your .
  • Make sure this fits by entering your model number.
  • Replacement Federal Pacific Electric Stab-Lok circuit breaker manufactured new by Connecticut Electric
  • For use in Stab-Lok circuit breaker panels
  • Intertek ETL Listing to UL Standard 489 for US and Canada-Molded case circuit breakers
  • 10,000 AIC
  • 40 Amp
  • 120/240 VAC 2 Pole breaker in a 2″ thick body-NA style
  • Plug in type

See more product details

UBIZ270-New Zinsco QC70 Replacement. Two Pole 70 Amp Thick Series Manufactured by Connecticut Electric. Review

UBIZ270-New Zinsco QC70 Replacement. Two Pole 70 Amp Thick Series Manufactured by Connecticut Electric.

    This fits your .
  • Make sure this fits by entering your model number.
  • Replacement Zinsco circuit breaker manufactured new by Connecticut Electric
  • For use in Zinsco circuit breaker panels
  • Intertek ETL Listing to UL Standard 489 for US and Canada-Molded case circuit breakers
  • 10,000 AIC
  • 70 Amp
  • 120/240 VAC 2 Pole breaker in a 1 1/2″ body
  • Plug in type
  • May also be branded as Sylvania (ie Sylvania QC70)

See more product details

Product Description

Connecticut Electric manufactures new high quality replacement circuit breakers for Zinsco load centers that accept Zinsco QC style circuit breakers. Circuit breakers should only be replaced with new tested and Safety Agency Listed circuit breakers, never used or refurbished ones.

From the Manufacturer

This 120/240 volt Zinsco 70 amp, double pole, thick series replacement circuit breaker is used in a Zinsco load center and/or used for feeding Sub-Feed Panel Boxes. This is only a suggestion and cannot assure your compliance with all local codes. Please check local electrical codes before starting any electrical project.

Cutler Hammer CH240 Circuit Breaker, 2-Pole 40-Amp Review

Cutler Hammer CH240 Circuit Breaker, 2-Pole 40-Amp

    This fits your .
  • Make sure this fits by entering your model number.
  • 2 Pole, 40 Amp
  • Type CH for use in Cutler Hammer load centers
  • Requires two 3/4-inch spaces

See more product details

UBIP240-New Pushmatic P240 Replacement. Two Pole 40 Amp Circuit Breaker Manufactured by Connecticut Electric. Review

UBIP240-New Pushmatic P240 Replacement. Two Pole 40 Amp Circuit Breaker Manufactured by Connecticut Electric.

    This fits your .
  • Make sure this fits by entering your model number.
  • Replacement Pushmatic circuit breaker manufactured new by Connecticut Electric
  • For use in Pushmatic circuit breaker panels
  • Intertek ETL Listing to UL Standard 489 for US and Canada-Molded case circuit breakers
  • 10,000 AIC
  • 40 Amp
  • 120/240 VAC 2 Pole breaker
  • Bolt on type
  • May also be branded as Bulldog (ie Bulldog P240)

See more product details

Connecticut Electric UBITB-A220 New Challenger MH220 Type-A Replacement. Two Pole 20 Amp Clip Circuit Breaker Manufactured Review

Connecticut Electric UBITB-A220 New Challenger MH220 Type-A Replacement. Two Pole 20 Amp Clip Circuit Breaker Manufactured

    This fits your .
  • Make sure this fits by entering your model number.
  • Replacement Challenger MH220 Type A circuit breaker manufactured new by Connecticut Electric
  • For use in Challenger Type A circuit breaker panels
  • Intertek ETL Listing to UL Standard 489-Molded case circuit breakers
  • 10,000 AIC
  • 20 Amp
  • 120/240 VAC 2 Pole breaker 1″ thin type breakers
  • Plug in type

Show more

Product Description

Connecticut Electric manufactures new high quality replacement circuit breakers for Challenger load centers that accept Challenger Type A style circuit breakers. Circuit breakers should only be replaced with new testd and Safety Agency Listed circuit breakers, never used or refurbished ones.

From the Manufacturer

This 120/240 volt Challenger “A” Series 20 amp, double pole replacement circuit breaker is used in a Challenger load center. Typical applications, up to 8,800 watts, include electric baseboard heat, fan forced heat and 240 volt air conditioners (up to 23,000 BTU). These are only suggested applications and cannot assure compliance with all local codes. Please check local electrical codes before starting any electrical project.

American/Federal Pacific Circuit Breaker, 1-Pole 20-Amp Thick Series Review

American/Federal Pacific Circuit Breaker, 1-Pole 20-Amp Thick Series

    This fits your .
  • Make sure this fits by entering your model number.
  • 1 Pole, 20 Amp
  • Type NA for use in Federal Pacific load centers
  • Thick series, requires one 1-inch space

See more product details

Product description

1- Federal Pacific Circuit Breaker NA20 1-Pole 20-Amp Thick Series NA120

From the Manufacturer

This 120 volt Federal Pacific Electric 20 amp, single pole, thick series replacement circuit breaker is used in a Federal Pacific load center. Typical applications, up to 2,200 watts, include kitchen circuits, branch circuits, wall receptacles, electric heaters (up to 1,650 watts), dishwashers, refrigerators, freezers, washing machines, window air conditioners (110V, up to 5,500 BTU) and electric motors (3/4 hp to 1-1/4 hp). These are only suggested applications and cannot assure compliance with all local codes. Please check local electrical codes before starting any electrical project.

Connecticut Electric UBITB-A115R New Challenger MH115-R Type-A Replacement. One Pole 15 Amp Right Clip Circuit Breaker Manufactured Review

Connecticut Electric UBITB-A115R New Challenger MH115-R Type-A Replacement. One Pole 15 Amp Right Clip Circuit Breaker Manufactured

    This fits your .
  • Make sure this fits by entering your model number.
  • Replacement Challenger MH115-R Type A circuit breaker manufactured new by Connecticut Electric
  • For use in Challenger Type A circuit breaker panels
  • Intertek ETL Listing to UL Standard 489-Molded case circuit breakers
  • 10,000 AIC
  • 15 Amp, Right Clip
  • 120 VAC 1 Pole breaker 1/2″ thin type breaker
  • Plug in type
  • May also be branded: Murray, Crouse-Hinds, or Sylvania

See more product details

Product Description

Connecticut Electric manufactures new high quality replacement circuit breakers for Challenger load centers that accept Challenger Type A style circuit breakers. Circuit breakers should only be replaced with new testd and Safety Agency Listed circuit breakers, never used or refurbished ones.

From the Manufacturer

This 120 volt Challenger “A” Series 15 amp, single pole, With Right Side Clip, replacement circuit breaker is used in a Challenger load center. Typical applications, up to 1,800 watts, include fixed lighting circuits, branch circuits, wall receptacles, electric motors (1/4 hp to 1/2 hp), attic fans and garbage disposals. These are only suggested applications and cannot assure compliance with all local codes. Please check local electrical codes before starting any electrical project.

Scroll To Top