Bussmann FRN-R-40 40 Amp Fusetron Dual Element Time-Delay Current Limiting Fuse Class RK5, 250V UL Listed Review

Bussmann FRN-R-40 40 Amp Fusetron Dual Element Time-Delay Current Limiting Fuse Class RK5, 250V UL Listed

Product Description

Description: advanced protection, energy efficient class Rk5 dual element, current-limiting, time-delay fuses with optional open fuse indication on select ratings.^^Features: provides motor overload, ground fault and short-circuit protection helps protect Motors against burnout from overloads helps protect Motors against burnout from single-phasing on three-phase systems simplifies and improves blackout prevention (selective coordination) dual-element fuses can be applied in circuits subject to temporary motor overloads and surge currents to provide both high performance short-circuit and overload protection the overload element provides protection against low level overcurrent of overloads and will hold an overload which is five times greater than the ampere rating of the fuse for a minimum of ten seconds.^^Time-delay – 10 seconds (minimum) at 500% of rated current (8 seconds for 110-30a sizes).^^agency information: ce, UL listed, std. 248-12, class rk-5, guide jddz, file E4273 CSA certified, C22.2 no. 248.12, class 1422-02, file 53787.

From the Manufacturer

Heavy duty time-delay fuse used in motor protection. When sized correctly, it helps protect motors from burnout caused by overloads or single-phasing. The time-delay feature allows the initial startup current surge for typical motors to pass, but opens prior to motor burnout when longer, dangerous overloads are present. In addition, the dual-element design opens in as little as 0.004 second if the fuse experiences short-circuit conditions. UL Listed Class R (IR: 200kA). Groove in end cap or notch in knife blade permit the fuse to be used in Class H, Class K or Class R fuse blocks. Cartridge fuses are used to protect motors and branch circuits where higher amps or volt ratings are required. They are available in a wide variety of sizes, amp and volt ratings up to 600Vac and 600 amps. Cartridge fuses are used extensively in commercial, industrial and agricultural applications as well as residential fuse panels, air conditioning, pumps, appliances and other equipment. Cartridge fuses are available in two types. General Purpose fuses have no time-delay and protect fuse panels, appliances and branch circuits. Heavy- Duty fuses have a time-delay feature, allowing momentary motor startups. Both are available in 250Vac and 600Vac versions with catalog symbol and amp rating stamped on the knife blade or end cap.

VOODOO (3 Pack) – Gold ANL Fuse Holder 2/0 or 1/0 0 Gauge no terminals Needed (150 Amp Fuse) Review

VOODOO (3 Pack) - Gold ANL Fuse Holder 2/0 or 1/0 0 Gauge no terminals Needed (150 Amp Fuse)

    This fits your .
  • Make sure this fits by entering your model number.
  • Gold Plated Brass Hardware
  • Alan Screw Clamping of Wire
  • Clear Protective Plastic Housing
  • Mounting holes on each end
  • Includes 3 ANL Fuses

See more product details

Size:150 Amp Fuse

Qty 3 –  125 Amp ANL Fuse – Holder Voodoo Gold 1/0 0 Gauge – no terminals needed
Voodoo inline ANL fuse block
2/0 or 1/0 AWG in and 2/0 or1/0 AWG out AWG
Solid brass blocks
Gold plated

BUSSMANN FUSES BP/NON-50 250V K5 One-Time 50 Amp Low-Voltage Cartridge Fuse Review

BUSSMANN FUSES BP/NON-50 250V K5 One-Time 50 Amp Low-Voltage Cartridge Fuse

    This fits your .
  • Make sure this fits by entering your model number.
  • Quantity: 2 Pack
  • 50A, Type NON Cartridge Fuse
  • General Purpose, 250V
  • Protect lighting, heating, and other circuits not subject to temporary surges and where available short-circuit currents are relatively low
  • ONE-TIME fuses do not have a time delay feature and thus should not be specified in circuits where large transients or motor overloads occur
  • For general purpose circuits, size at ampere rating of circuit
  • For motor circuits, size at 300% to 400%
  • UL Listed – 250Vac: Class K5 (0-60A), Std. 248-9

See more product details

Product Description

2 Pack, 50A, Type NON Cartridge Fuse, General Purpose, 250V, Dimensions: 2.75″L x 1.375″W x 0.50″H, Carded.

From the Manufacturer

One-time general purpose non-current limiting fuse used in lighting circuits, main panel protection, and other circuits that don’t contain large electric motors or inductive loads. One to 60 amp fuses UL Listed Class K5 (IR: 50kA). 70 to 600 amp fuses UL Class H (IR: 10kA). Cartridge fuses are used to protect motors and branch circuits where higher amps or volt ratings are required. They are available in a wide variety of sizes, amp and volt ratings up to 600Vac and 600 amps. Cartridge fuses are used extensively in commercial, industrial and agricultural applications as well as residential fuse panels, air conditioning, pumps, appliances and other equipment. Cartridge fuses are available in two types. General Purpose fuses have no time-delay and protect fuse panels, appliances and branch circuits. Heavy- Duty fuses have a time-delay feature, allowing momentary motor startups. Both are available in 250Vac and 600Vac versions with catalog symbol and amp rating stamped on the knife blade or end cap.

Littelfuse 00940400ZGLO Smart Glow Blade Style Assorted Multi-Pack Fuse – 42 Piece Review

Littelfuse 00940400ZGLO Smart Glow Blade Style Assorted Multi-Pack Fuse - 42 Piece

    This fits your .
  • Make sure this fits by entering your model number.
  • 42 assorted Smart Glo ATO blade fuses
  • Glowing light tells you when the fuse is blown
  • Currently found on most cars, trucks, buses and off road vehicles world-wide
  • Littelfuse designed industry standard color coding to indicate amp rating

See more product details

Patented and introduced in 1976 by Littelfuse, it became the international fuse standard by 1981. It is currently found on most cars, trucks, buses and off road vehicles world-wide. Features Littelfuse designed industry standard color coding to indicate amp rating.

Bussmann FRN-R-600, 600 Amp (600A) 250V Fusetron Dual Element Time-Delay Current Limiting Class RK5 Fuse, UL Listed Review

Bussmann FRN-R-600, 600 Amp (600A) 250V Fusetron Dual Element Time-Delay Current Limiting Class RK5 Fuse, UL Listed

    This fits your .
  • Make sure this fits by entering your model number.
  • Fuse Class RK5 Slow Blow Acting 600A 250V

See more product details

Fuse Class RK5 Slow Blow Acting 600A 250V

Bussmann FRS-R-30 Tron FRS-R Energy Efficient Non-Indicating Time Delay Fuse, 600 Vac/300 Vdc, 30 Amp Review

Bussmann FRS-R-30 Tron FRS-R Energy Efficient Non-Indicating Time Delay Fuse, 600 Vac/300 Vdc, 30 Amp

Product Description

Cooper Busman Time Delay Fuse, Energy Efficient, Non-Indicating, Series: Fuse Tron, FRS-R, 30 A, 600 VAC/300 VDC, 200 kA at 600 VAC, 20 kA at 300 VDC Interrupt, Class: RK5, 10 sec at 500% Response, Ferrule, Cylindrical, Rejection Body, Dual Element, Fiberglass, Brass End Cap, 0.81 in Diameter, 5 in Length, Fuse Holder Code: P, Combination Starters. Value not found.

From the Manufacturer

Heavy duty time-delay fuse used in motor protection. When sized correctly, it helps protect motors from burnout caused by overloads or single-phasing. The time-delay feature allows the initial startup current surge for typical motors to pass, but opens prior to motor burnout when longer, dangerous overloads are present. In addition, the dual-element design opens in as little as 0.004 second if the fuse experiences short-circuit conditions. UL Listed Class R (IR: 200kA). Groove in end cap or notch in knife blade permit the fuse to be used in Class H, Class K or Class R fuse blocks. Cartridge fuses are used to protect motors and branch circuits where higher amps or volt ratings are required. They are available in a wide variety of sizes, amp and volt ratings up to 600Vac and 600 amps. Cartridge fuses are used extensively in commercial, industrial and agricultural applications as well as residential fuse panels, air conditioning, pumps, appliances and other equipment. Cartridge fuses are available in two types. General Purpose fuses have no time-delay and protect fuse panels, appliances and branch circuits. Heavy- Duty fuses have a time-delay feature, allowing momentary motor startups. Both are available in 250Vac and 600Vac versions with catalog symbol and amp rating stamped on the knife blade or end cap.

Bussmann BP/SC-20 20 Amp Time-Delay Class G Melamine Tube, 600V UL Listed Carded, 2-Pack Review

Bussmann BP/SC-20 20 Amp Time-Delay Class G Melamine Tube, 600V UL Listed Carded, 2-Pack

    This fits your .
  • Make sure this fits by entering your model number.
  • Quantity: 2 Pack
  • 20A, Type SC Cartridge Fuse
  • Compact, Time Lag Feature
  • 13/32″ Diameter, 300V
  • Compact branch-circuit unit with high interrupting rating and current-limitation
  • With 600V rating, it can be used in 120/208, 120/240 and 277/480V circuits
  • Length variations relative to case size make this a “rejection” type fuse

Show more

Bussmann BP/T-20 20 Amp Type T Time-Delay Dual-Element Edison Base Plug Fuse, 125V Ul Listed Carded, 2-Pack Review

Bussmann BP/T-20 20 Amp Type T Time-Delay Dual-Element Edison Base Plug Fuse, 125V Ul Listed Carded, 2-Pack

    This fits your .
  • Make sure this fits by entering your model number.
  • 20A, Type T Plug Fuse
  • Time Delay Fusetron
  • Dimensions: 4.75″L x 4.76″W x 4.77″H, Carded
  • Heavy Duty Time-Delay Plug Fuse used to protect critical motor circuits or motors that cycle on/off frequently
  • An industrial/commercial grade product with exclusive dual element construction. Edison base size. These fuses thread into fuse receptacles
  • The Heavy Duty T fuses are industrial strength products, featuring Bussmann’s exclusive Dual-Element construction
  • This spring loaded design provides superior short circuit and overload protection
  • The T fuses have more time-delay than the medium duty fuses in order to better protect industrial motors and critical residential circuits

See more product details

Product Description

2 Pack, 20A, Type T Plug Fuse, Time Delay Fusetron, Dimensions: 2.75″L x 1.375″W x 0.625″H, Carded. Heavy duty dual-element construction for motor circuits. Edison base threads into non-rejection fuse receptacles. Superior overload and short-circuit protection.

From the Manufacturer

Type T 125Vac Dual-Element, Time-Delay, Edison Base Plug Fuse. Heavy-Duty Type T fuses for critical circuit protection. Used for air conditioners, furnace blower motors, swimming pool pumps, deep freezers or any circuit where motors frequently turn on and off. Use for all commercial applications. The Type T plug fuse is an industrial strength product. It provides superior protection, yet will not open under repeated motor startups. Available in a wide amp range to permit exact sizing for motor protection. Plug fuses thread into fuse receptacles. Two types of threaded fuses are available: Edison Base (brass threads) and Rejection Base (porcelain threads). The two are not interchangeable. The heavy-duty fuses (T or S) are industrial strength products featuring the exclusive Cooper Bussmann dual-element construction. This spring loaded design provides superior short-circuit and overload protection. The T or S fuses have more time-delay than medium-duty fuses in order to better protect motors and critical residential circuits. Plug fuses are rated for a maximum of 125Vac. Plug fuses are often used in residential and industrial branch circuit and motor protection. Fuses are used to protect furnace blower motors, pumps, power tools, garage door openers, etc. Motor protection fuses are usually used in conjunction with branch circuit protection. The fuse is often located in a box cover unit. Plug fuses provide a compact and inexpensive method to prevent damage to electrical motors. They help reduce downtime and lower maintenance costs by opening the circuit when a dangerous overload is present. When used for residential branch circuit protection, fuses are typically located in the main fuse panel.