Murray MP21520 1/2-Inch Frame Breaker with Two Single Pole 15-Amp and one Double Pole 20-Amp Breakers Review

Murray MP21520 1/2-Inch Frame Breaker with Two Single Pole 15-Amp and one Double Pole 20-Amp Breakers

    This fits your .
  • Make sure this fits by entering your model number.
  • UL Listed breaker
  • 10 KAIC rated
  • Two single pole and one double pole breaker combined in one
  • UL Type MH-T

See more product details

Murray breakers are intended for use in Murray and Crouse Hinds type load centers. These breakers are plug in style and are on a 1/2-Inch per pole format. See the wiring diagram on the load center for breaker type acceptance. The 1/2-Inch breakers will only fit in designed spaces within certain load centers. The wiring diagram will state if the MH-T breakers are accepted and will detail where they can be installed. Murray strongly recommends against the use of “used” breakers. The installation of used breakers in a Murray panel will void the warranty on the panel. Murray does not sell used breakers and has not approved any 3rd party sellers to do so.

MP240 40-Amp Double Pole Type MP-T Circuit Breaker Review

MP240 40-Amp Double Pole Type MP-T Circuit Breaker

    This fits your .
  • Make sure this fits by entering your model number.
  • Double pole, 40 Amp, 240V type MP-T Circuit Breaker
  • 10,000 AIC interrupting rating
  • Murray type MP-T circuit breakers provide easy plug-in connections in Murray enclosures and the time saving insta-wire feature
  • Compatible with Murray rock solid load centers
  • Use for overload and short-circuit protection of your electrical system

See more product details

Murray LW004NRU Load Center, 4 Space, 8 Circuit, 125A, Main Lug Review

Murray LW004NRU Load Center, 4 Space, 8 Circuit, 125A, Main Lug

    This fits your .
  • Make sure this fits by entering your model number.
  • The product is good to use
  • The product is of high quality
  • Manufactured in China

See more product details

Product Description

Murray, 125a, main lug load center, 4 spaces, 8 circuits, outdoor application. The product is of high quality.

From the Manufacturer

Murray 4 space, 8 circuit, Main Lug Load Center is 125 Amp rated. This enclosure is outdoor rated.

Murray MP230GF 30-Amp 2 Pole 240-Volt Ground Fault Circuit Interrupter Review

Murray MP230GF 30-Amp 2 Pole 240-Volt Ground Fault Circuit Interrupter

    This fits your .
  • Make sure this fits by entering your model number.
  • 30-Amp
  • 2 Pole
  • Plug in type
  • 2-Inch Frame
  • UL listed

See more product details

Product Description

Murray GFCI plug in circuit breakers are intended for use in Murray load centers or meter combinations. The single pole Murray breakers may be used in 1 or 3-phase load centers and are 120V rated. To ensure the warranty on a Murray panel is not voided, the use of Murray breakers is required. The GFCI is intended for areas required by code to have ground fault protection, such as bathrooms, kitchens, and outdoor circuits. Check with your local electrical inspector to confirm. The use of a double pole AFCI allows for shared neutral applications in which two circuits will share a common neutral. Murray strongly recommends against the use of “used” breakers. The installation of used breakers in a Murray panel will void the warranty on the panel. Murray does not sell used breakers and has not approved any 3rd party sellers to do so.

From the Manufacturer

Murray GFCI plug in circuit breakers are intended for use in Murray load centers or meter combinations. The single pole Murray breakers may be used in 1 or 3-phase load centers and are 120V rated. To ensure the warranty on a Murray panel is not voided, the use of Murray breakers is required. The GFCI is intended for areas required by code to have ground fault protection, such as bathrooms, kitchens, and outdoor circuits. Check with your local electrical inspector to confirm. The use of a double pole AFCI allows for shared neutral applications in which two circuits will share a common neutral.

Murray LC004VS Load Center, 200A CB Enclosure Review

Murray LC004VS Load Center, 200A CB Enclosure

    This fits your .
  • Make sure this fits by entering your model number.
  • 200 Amp max
  • Breaker not included
  • 2 breaker spaces
  • Circuit breaker enclosure
  • Indoor rated

See more product details

Product description

Murray products have a rich tradition of quality and reliability that still lives on today. At the heart of the Murray offering is the Rock Solid load center – designed for those customers that prefer an out-board neutral design and metal base pan for installing breakers. The Rock Solid load center and Murray products remain an important part of the Siemens portfolio. Murray Rock Solid Load Centers are the highest quality, most versatile design in the industry.Single phase, 200-Amp main lug load center with 2 spaces/4 circuitsAluminum bus barEliminated “notching” needed for standard load centersInvertible for bottom feed applicationsTrim mounting tabs free up both hands for driving trim screwsIdeal for narrow stud applicationsNEMA type 1: enclosure is intended for indoor use primarily to provide protection against contact with the enclosed equipment in locations where unusual service conditions do not exist

From the Manufacturer

Murray indoor rated, 200 Amp max, circuit breaker enclosure accepts a two pole Murray breaker from 15 to 200 Amps and is ideal for use as a disconnecting means for a building, house, or a piece of equipment

Murray MBK200M 200-Amp Main Circuit Breaker for Use in Rock Solid Type Load Centers Review

Murray MBK200M 200-Amp Main Circuit Breaker for Use in Rock Solid Type Load Centers

    This fits your .
  • Make sure this fits by entering your model number.
  • 200-Amp
  • Main breaker kit
  • Bolt-on type
  • For use with 200 or 225-Amp Rock Solid type load centers
  • UL listed

See more product details

Product Description

Murray main breaker kits are used to convert the Rock Solid type of main lug load centers to main breaker load centers, or can be used as a replacement main breaker in main breaker type Rock Solid load centers. Rock Solid load centers are the current load center in production and went into production in 2003. Check the load center wiring diagram for confirmation. Murray strongly recommends against the use of “used” breakers.  The installation of used breakers in a Murray panel will void the warranty on the panel.  Murray does not sell used breakers and has not approved any 3rd party sellers to do so.

From the Manufacturer

Murray main breaker kits are used to convert the Rock Solid type of main lug load centers to main breaker load centers, or can be used as a replacement main breaker in main breaker type Rock Solid load centers. Rock Solid load centers are the current load center in production and went into production in 2003. Check the load center wiring diagram for confirmation.

MP2125 125-Amp Double Pole Type MP-T Circuit Breaker Review

MP2125 125-Amp Double Pole Type MP-T Circuit Breaker

    This fits your .
  • Make sure this fits by entering your model number.
  • Double pole, 125 Amp, 240V type MP-T Circuit Breaker
  • 10,000 AIC interrupting rating
  • Murray type MP-T circuit breakers provide easy plug-in connections in Murray enclosures and the time saving insta-wire feature
  • Compatible with Murray rock solid load centers
  • Use for overload and short-circuit protection of your electrical system

See more product details

Product Description

Murray offers a wide array of thermal-magnetic circuit breakers that are the key element for overload and short-circuit protection of your home’s electrical system. To provide additional protection Murray offers circuit breakers to protect against severe electrical shock or electrocution, mitigate the risk of electrical fires and protect against damaging surges and voltage spikes. Circuit breakers are intended for switching and protection of your home’s wiring from high temperatures caused by excess current higher than the rating of the wire. While thermal-magnetic circuit breakers are the key element for overload and short-circuit protection of your electrical system, there are potentially dangerous conditions that do not involve over current. Murray strongly recommends against the use of “used” breakers. The installation of used breakers in a Murray panel will void the warranty on the panel. Murray does not sell used breakers and has not approved any 3rd party sellers to do so.

From the Manufacturer

Murray plug in circuit breakers are intended for use in Murray load centers or meter combinations. The double pole Murray breakers may be used in 1 or 3-phase load centers and are 240V rated. To ensure the warranty on a Murray panel is not voided, the use of Murray breakers is required.

Murray MP220AFC 20-Amp 2 Pole 120-Volt Combination Type Arc Fault Circuit Interrupter Review

Murray MP220AFC 20-Amp 2 Pole 120-Volt Combination Type Arc Fault Circuit Interrupter

    This fits your .
  • Make sure this fits by entering your model number.
  • Combination type AFCI
  • 2 Pole
  • Plug in type
  • 20-Amp
  • UL listed

See more product details

Product Description

Murray AFCI plug in circuit breakers are intended for use in Murray load centers or meter combinations. The double pole Murray breakers may be used in single or 3-phase load centers and are 240V rated. To ensure the warranty on a Murray panel is not voided, the use of Murray breakers is required. The combination type AFCI is for use in areas enforcing the 2008 or newer National Electric Code. Check with your local electrical inspector to confirm. The use of a double pole AFCI allows for shared neutral applications in which two circuits will share a common neutral. Murray strongly recommends against the use of “used” breakers. The installation of used breakers in a Murray panel will void the warranty on the panel. Murray does not sell used breakers and has not approved any 3rd party sellers to do so.

From the Manufacturer

Murray AFCI plug in circuit breakers are intended for use in Murray load centers or meter combinations. The double pole Murray breakers may be used in single or 3-phase load centers and are 240V rated. To ensure the warranty on a Murray panel is not voided, the use of Murray breakers is required. The combination type AFCI is for use in areas enforcing the 2008 or newer National Electric Code. Check with your local electrical inspector to confirm. The use of a double pole AFCI allows for shared neutral applications in which two circuits will share a common neutral.

Murray MPP2200 120/240-Volt 4-pole type MPP 200-Amp Main Breaker Review

Murray MPP2200 120/240-Volt 4-pole type MPP 200-Amp Main Breaker

    This fits your .
  • Make sure this fits by entering your model number.
  • UL Listed breaker
  • 10 KAIC rated
  • For use in multi-family metering products
  • UL Type MPP

See more product details

Siemens type MPP, MPP-HT, and MPP-MT breakers are intended for use in Murray panels and multi-family metering products where specified. Check the panel’s wiring diagram for acceptance. Siemens strongly recommends against the use of “used” breakers. The installation of used breakers in a Siemens panel will void the warranty on the panel. Siemens does not sell used breakers and has not approved any 3rd party sellers to do so.

MP2100 100-Amp Double Pole Type MP-T Circuit Breaker Review

MP2100 100-Amp Double Pole Type MP-T Circuit Breaker

    This fits your .
  • Make sure this fits by entering your model number.
  • Double pole, 100 Amp, 240V type MP-T Circuit Breaker
  • 10,000 AIC interrupting rating
  • Murray type MP-T circuit breakers provide easy plug-in connections in Murray enclosures and the time saving insta-wire feature
  • Compatible with Murray rock solid load centers
  • Use for overload and short-circuit protection of your electrical system

See more product details