- Make sure this fits by entering your model number.
- UL Listed
- Panel board mounting
- single pole
- Type BL
For use on all Siemens loadcenters, main lug, main breaker and meter socket; plus enclosed circuit breakers Nos. WB2225, WB3225.
Siemens 2-inch Hub for use on Siemens or Murray panels that call for an HS type hub. Check the wiring diagram of the panel to determine which hub type is required.
Siemens Meter Main and Meter Load Center Combination provides a full range of Meter Combination Load Centers and Meter Mains that are built for safety ease of installation and long term quality. A 200 Amp main breaker is installed along with a 20 space, 40 circuit interior. The enclosure is flush mount, NEMA 3R (outdoor) rated and is fabricated from Galvanized steel with a baked on polyester powder coating finish. The enclosure is designed to fit between standard 16″ centered studs. The meter cover is ring type and the ring is provided. This panel is rated for over head service feed only.
Murray GFCI plug in circuit breakers are intended for use in Murray load centers or meter combinations. The single pole Murray breakers may be used in 1 or 3-phase load centers and are 120V rated. To ensure the warranty on a Murray panel is not voided, the use of Murray breakers is required. The GFCI is intended for areas required by code to have ground fault protection, such as bathrooms, kitchens, and outdoor circuits. Check with your local electrical inspector to confirm. The use of a double pole AFCI allows for shared neutral applications in which two circuits will share a common neutral. Murray strongly recommends against the use of “used” breakers. The installation of used breakers in a Murray panel will void the warranty on the panel. Murray does not sell used breakers and has not approved any 3rd party sellers to do so.
Murray GFCI plug in circuit breakers are intended for use in Murray load centers or meter combinations. The single pole Murray breakers may be used in 1 or 3-phase load centers and are 120V rated. To ensure the warranty on a Murray panel is not voided, the use of Murray breakers is required. The GFCI is intended for areas required by code to have ground fault protection, such as bathrooms, kitchens, and outdoor circuits. Check with your local electrical inspector to confirm. The use of a double pole AFCI allows for shared neutral applications in which two circuits will share a common neutral.
Littelfuse MNI super value kit cover all of the professional technician’s circuit protection needs. Littelfuse offers the most comprehensive circuit protection kits on the market today addressing the needs of the Professional Service Center and Road Service Operation with genuine Littelfuse OEM fuses. Assortments are packaged in tough plastic storage containers perfect for the parts drawer, tool box, under counter or road service vehicle. The MINI super value pack fuse assortments are designed for the professional installer who needs a larger quantity and variety of fuses at the point of installation. All assortments are packaged bulk in plastic compartmentalized storage containers. (5) MINI 3, (5) MINI 5, (5) MINI 7.5, (5) MINI 10, (5) MINI 15, (5) MINI 20, (5) MINI 25, (5) MINI 30
125a, main lug convertible load center, flush mount, 8 space circuit, 16 single poles, #tgl2p equipment ground kit when used as service entrance.
Bussman BP/FRN-R-30ID 30 Amp EasyIDÂ? Heavy-Duty Time Delay Fuse 2 Count